How To Use Resmed Bipap Machine Lumis 100 With Humidifier
Here are the steps for using the ResMed BiPAP machine model
Lumis 100 with a humidifier:
1. Connect the humidifier: First,
ensure that you have a compatible humidifier for your ResMed BiPAP machine
model Lumis 100. You can check the user manual or contact the manufacturer to
confirm this. Once you have confirmed the compatibility, connect the humidifier
to the machine. The humidifier should attach to the side of the machine, and
there should be a hose connecting the two. Ensure that the hose is securely
connected to both the machine and the humidifier.
2. Fill the humidifier: Once the
humidifier is connected, you need to fill it with distilled water. Do not use
tap water as it can cause mineral buildup in the humidifier and damage the
machine. Open the lid of the humidifier and fill it with distilled water up to
the maximum fill line. Do not overfill the humidifier as it may cause water to
spill into the machine and damage it.
3. Install the air filter: The ResMed
BiPAP machine model Lumis 100 has an air filter that needs to be installed
before use. Locate the air filter compartment on the back of the machine and
open it. Remove the old air filter and insert a new one. Ensure that the filter
is properly seated in the compartment before closing it.
4. Power on the machine: Connect the
machine to a power outlet and turn it on by pressing the power button. The
machine will perform a self-test and display the start-up screen. Wait for the
self-test to complete before proceeding.
5. Adjust settings: Once the machine is
powered on, you can adjust the settings as needed. The ResMed BiPAP machine
model Lumis 100 has various settings that you can adjust, such as the pressure,
humidity level, and ramp time. You can also set the language and time on the
machine. To adjust the settings, use the controls on the machine or the remote
control that comes with it. Refer to the user manual for detailed instructions
on how to adjust the settings.
6. Connect the mask: Attach the mask to
the machine and adjust it to fit comfortably. There are various types of masks
available for the ResMed BiPAP machine model Lumis 100, such as nasal masks,
full-face masks, and nasal pillows. Choose the mask that is most comfortable
for you and fits properly. To attach the mask, connect it to the tubing on the
machine and adjust the straps to fit securely. Ensure that there are no leaks
around the mask.
7. Start therapy: Once the mask is in
place and the settings are adjusted, you can start your therapy by pressing the
start button. The machine will begin delivering pressurized air to your
airways, which helps to keep them open during sleep. The machine will also
deliver humidified air to your airways if you have connected the humidifier.
8. Monitor and adjust as needed:
Throughout your therapy, monitor your comfort level and adjust the settings as
needed. You may need to make adjustments to the humidity level, pressure, or
other settings to ensure you are receiving the most effective therapy. For
example, if you experience dryness in your mouth or nose, you may need to increase
the humidity level. If you experience discomfort around the mask, you may need
to adjust the straps or try a different mask.
9. Maintain and clean the machine: It
is important to maintain and clean your ResMed BiPAP machine model Lumis 100
regularly to ensure optimal performance and hygiene. Refer to the user manual
for instructions on how to clean the machine and its components. Generally, the
machine should be cleaned every week, and the humidifier chamber should be
cleaned daily. To clean the humidifier chamber, disassemble it and