How To Use Resmed Bipap Machine Model S9 with Humidifier
Here
are the steps for using the ResMed BiPAP machine model S9 VPAP with a
humidifier:
1.
Connect
the humidifier: First, ensure that you have a compatible humidifier for your
ResMed BiPAP machine model S9 VPAP. You can check the user manual or contact
the manufacturer to confirm this. Once you have confirmed the compatibility,
connect the humidifier to the machine. The humidifier should attach to the side
of the machine, and there should be a hose connecting the two. Ensure that the
hose is securely connected to both the machine and the humidifier.
2.
Fill
the humidifier: Once the humidifier is connected, you need to fill it with
distilled water. Do not use tap water as it can cause mineral buildup in the
humidifier and damage the machine. Open the lid of the humidifier and fill it
with distilled water up to the maximum fill line. Do not overfill the
humidifier as it may cause water to spill into the machine and damage it.
3.
Install
the air filter: The ResMed BiPAP machine model S9 VPAP has an air filter that
needs to be installed before use. Locate the air filter compartment on the back
of the machine and open it. Remove the old air filter and insert a new one.
Ensure that the filter is properly seated in the compartment before closing it.
4.
Power
on the machine: Connect the machine to a power outlet and turn it on by
pressing the power button. The machine will perform a self-test and display the
start-up screen. Wait for the self-test to complete before proceeding.
5.
Adjust
settings: Once the machine is powered on, you can adjust the settings as
needed. The ResMed BiPAP machine model S9 VPAP has various settings that you
can adjust, such as the pressure, humidity level, and ramp time. You can also
set the language and time on the machine. To adjust the settings, use the
controls on the machine or the remote control that comes with it. Refer to the
user manual for detailed instructions on how to adjust the settings.
6.
Connect
the mask: Attach the mask to the machine and adjust it to fit comfortably.
There are various types of masks available for the ResMed BiPAP machine model
S9 VPAP, such as nasal masks, full-face masks, and nasal pillows. Choose the
mask that is most comfortable for you and fits properly. To attach the mask,
connect it to the tubing on the machine and adjust the straps to fit securely.
Ensure that there are no leaks around the mask.
7.
Start
therapy: Once the mask is in place and the settings are adjusted, you can start
your therapy by pressing the start button. The machine will begin delivering
pressurized air to your airways, which helps to keep them open during sleep.
The machine will also deliver humidified air to your airways if you have
connected the humidifier.
8.
Monitor
and adjust as needed: Throughout your therapy, monitor your comfort level and
adjust the settings as needed. You may need to make adjustments to the humidity
level, pressure, or other settings to ensure you are receiving the most
effective therapy. For example, if you experience dryness in your mouth or
nose, you may need to increase the humidity level. If you experience discomfort
around the mask, you may need to adjust the straps or try a different mask.
9.
Maintain
and clean the machine: It is important to maintain and clean your ResMed BiPAP
machine model S9 VPAP regularly to ensure optimal performance and hygiene.
Refer to the user manual for instructions on how to clean the machine and its
components. Generally, the machine should be cleaned every week, and the
humidifier