Review auto cpap machine resmed model s8 with humidifier

Review auto cpap machine Resmed Model S8 with Humidifier

Auto CPAP machines are a type of continuous positive airway pressure (CPAP) machine that can automatically adjust the pressure delivered to the patient based on their individual needs. The ResMed S8 AutoSet II is one such machine that is designed to provide effective therapy for patients suffering from sleep apnea.

how to use auto cpap machine resmed model s8 with humidifier


The S8 AutoSet II comes with a built-in humidifier that helps to reduce dryness and irritation in the patient's airway. In this article, we will discuss how to use the ResMed S8 AutoSet II with the humidifier.

1.      Initial Setup

The first step in using the ResMed S8 AutoSet II with the humidifier is to set up the machine itself. Here are the steps to follow:

·         Plug the machine into an electrical outlet

·         Attach the humidifier to the machine, making sure it is securely connected

·         Fill the humidifier with distilled water up to the maximum water level line

·         Connect the air tubing to the machine and the humidifier

·         Turn the machine on and wait for it to warm up

2.      Adjusting the Humidifier Settings

The ResMed S8 AutoSet II comes with several humidifier settings that can be adjusted according to your personal preference. Here's how to do it:

·         Press the "Humidity" button on the machine to access the humidifier settings

·         Use the arrow buttons to adjust the humidity level. The recommended humidity level is between 2 and 5.

·         You can also adjust the temperature of the humidifier by pressing the "Temperature" button and using the arrow buttons to increase or decrease the temperature.

·         Once you've set the desired humidity and temperature levels, press the "Start" button to begin therapy.

3.      Using the AutoSet Feature

The ResMed S8 AutoSet II comes with an AutoSet feature that allows the machine to automatically adjust the pressure based on the patient's breathing patterns. Here's how to use it:

·         Turn on the AutoSet feature by pressing the "AutoSet" button on the machine.

·         The machine will automatically adjust the pressure based on the patient's breathing patterns, providing the most comfortable and effective therapy possible.

4.      Cleaning the Machine

To ensure the machine continues to work effectively, it's important to clean it regularly. Here are some steps to follow:

·         Disconnect the machine from the power source and remove the air tubing and humidifier.

·         Clean the humidifier with soap and warm water, rinsing it thoroughly and allowing it to air dry.

·         Wipe the machine and air tubing with a damp cloth and allow it to air dry.

·         Reassemble the machine and humidifier, and connect the air tubing to the machine and the mask.

5.      Troubleshooting

If you encounter any issues while using the ResMed S8 AutoSet II with the humidifier, here are some troubleshooting steps to follow:

·         Check the power source to ensure the machine is properly plugged in

·         Ensure the humidifier is properly connected to the machine

·         Check the air tubing to ensure there are no leaks or blockages

·         Make sure the humidifier is filled with distilled water up to the maximum water level line

·         If the machine is not functioning properly, contact the manufacturer for assistance.

In conclusion, using the ResMed S8 AutoSet II with the humidifier is an effective way to manage sleep apnea symptoms. By following the steps outlined above, you can ensure the machine is set up correctly, adjust the humidifier settings according to your preference, and use the AutoSet feature to provide the most comfortable therapy possible. Don't forget to clean the machine regularly and troubleshoot any issues that may arise.

Post a Comment