How to use Auto Cpap Machine Philips model 60 series with
Humidifier
The Philips Respironics System One 60 Series Auto CPAP with
Humidifier is a machine designed to provide effective therapy for individuals
with sleep apnea. This machine comes with a built-in humidifier that can help
reduce dryness and irritation in the airway. In this article, we will discuss
how to use the Philips Respironics System One 60 Series Auto CPAP with
Humidifier.
1. Initial Setup
The
first step in using the Philips Respironics System One 60 Series Auto CPAP with
Humidifier is to set up the machine. Here are the steps to follow:
·
Plug
in the machine to an electrical outlet
·
Attach
the humidifier to the machine, making sure it is securely connected
·
Fill
the humidifier with distilled water up to the maximum water level line
·
Connect
the air tubing to the machine and the humidifier
·
Turn
on the machine and wait for it to warm up
2. Adjusting the Humidifier Settings
The
Philips Respironics System One 60 Series Auto CPAP with Humidifier has several
humidifier settings that can be adjusted according to your personal preference.
Here's how to do it:
·
Press
the "Home" button on the machine to access the main menu
·
Select
"Comfort" and then "Humidity Level"
·
Use
the arrow buttons to adjust the humidity level. The recommended humidity level
is between 2 and 5.
·
You
can also adjust the temperature of the humidifier by selecting
"Temperature" and using the arrow buttons to increase or decrease the
temperature.
·
Once
you've set the desired humidity and temperature levels, press the
"Back" button to return to the main menu.
3. Using the Auto-Adjusting Feature
The
Philips Respironics System One 60 Series Auto CPAP with Humidifier comes with
an auto-adjusting feature that can adjust the pressure based on the patient's
breathing patterns. Here's how to use it:
·
Turn
on the auto-adjusting feature by pressing the "Home" button and
selecting "Therapy Mode"
·
Select
"Auto-Adjusting" and then "Auto-Start"
·
The
machine will automatically adjust the pressure based on the patient's breathing
patterns, providing the most comfortable and effective therapy possible.
4. Using the Ramp Feature
The
Philips Respironics System One 60 Series Auto CPAP with Humidifier also comes
with a ramp feature that can gradually increase the pressure to the prescribed
level. Here's how to use it:
·
Press
the "Ramp" button on the machine to activate the ramp feature
·
Use
the arrow buttons to adjust the ramp time. The recommended ramp time is between
15 and 30 minutes.
·
The
machine will gradually increase the pressure to the prescribed level during the
ramp time, providing a more comfortable transition to therapy.
5. Cleaning the Machine
To
ensure the machine continues to work effectively, it's important to clean it
regularly. Here are some steps to follow:
·
Disconnect
the machine from the power source and remove the air tubing and humidifier.
·
Clean
the humidifier with soap and warm water, rinsing it thoroughly and allowing it
to air dry.
·
Wipe
the machine and air tubing with a damp cloth and allow it to air dry.
·
Reassemble
the machine and humidifier, and connect the air tubing to the machine and the
mask.
6. Troubleshooting
If
you encounter any issues while using the Philips Respironics System One 60
Series Auto CPAP with Humidifier, here are some troubleshooting steps to
follow:
·
Check
the power source to ensure the machine is properly plugged in
·
Ensure
the humidifier is properly connected to the machine
·
Check
the air tubing to ensure there are no leaks or blockages
·
Make
sure


0 Comments